I decided to rewire the Laser after my Big Green Resistor started smoking. I didn't think there was any harm leaving it in place.
I have now bypassed it and just joined the wires together.
I could not find out how to connect the digital Meter so I went back to using the Analog Meter.
Could someone tell me if this wiring sketch looks correct.
40W Tube Wiring Question
-
- Posts: 24
- Joined: Sun Sep 13, 2009 12:54 pm
- Contact:
-
- Posts: 4654
- Joined: Mon Jun 15, 2009 3:00 pm
- Contact:
Re: 40W Tube Wiring Question
This is a good connection diagram. Just need to pay a little attention to the polarity of the analog meter. If +/- reversed, the needle will swing to the opposite dirction. If that happened, no problem just swap the +/- connection on the meter
Marco
(in China)
Marco
(in China)
Who is online
Users browsing this forum: No registered users and 3 guests